Fire Risk Management

Our Services
Which fire safety service do you need?
Each service answers a different question:
| Service | Main purpose |
| Fire risk assessment | Evaluates risks to people from fire, considers existing precautions and identifies further measures needed. |
| Fire compartmentation survey | Examines the condition and continuity of fire-resisting construction, including relevant fire stopping. |
| Fire door survey | Examines fire door assemblies to identify defects affecting their condition, operation and intended performance. |
A fire risk assessment may identify the need for a specialist compartmentation or fire door survey. The scope of any further investigation should respond to the building’s circumstances and the evidence available.
Fire Risk Assessments
A fire risk assessment is a structured examination of fire hazards, the people who could be affected and the precautions needed to reduce risk.
Anstey Horne assesses the building’s physical fire precautions alongside its fire safety management arrangements. Depending on the premises, this includes escape routes, fire doors, detection and warning systems, emergency lighting, evacuation arrangements and maintenance records.
Our fire risk assessment reports explain:
- The areas inspected, sampling undertaken and any access limitations.
- The principal risks and existing fire safety measures.
- Recommended actions, ranked by risk and urgency.
- Where further specialist investigation is needed.
- The recommended review period and circumstances that should trigger an earlier review.
Types 1–4 fire risk assessments for blocks of flats
The four assessment types distinguish between the areas examined and whether destructive opening-up is involved.
| Assessment type | Areas considered | Inspection approach |
| Type 1 | Common parts, including consideration of flat entrance doors and separating construction. | Non-destructive. |
| Type 2 | Broadly the same scope as Type 1, with investigation of concealed construction. | Destructive inspection on a sampling basis. |
| Type 3 | Common parts and fire precautions within a sample of flats. | Non-destructive. |
| Type 4 | Common parts and a sample of flats, including concealed construction. | Destructive inspection on a sampling basis. |
The appropriate type depends on the building and the reasons for investigation. Intrusive assessment requires suitable access arrangements and an agreed plan for opening up and making good. A higher assessment number is not automatically the right choice for every building.
Pre-occupation fire risk assessments
A pre-occupation fire risk assessment helps identify fire safety issues that need attention before a building, or a phase of development, comes into use.
The assessment should reflect the intended occupation, available fire safety information and management arrangements. Its findings need to be reviewed as occupation and operational arrangements develop.
Fire compartmentation surveys
Fire compartmentation divides a building into fire-resisting sections designed to restrict the spread of fire and smoke.
A compartmentation survey examines the relevant barriers and their interfaces to identify defects or gaps that could undermine that protection.
Our surveys can include:
- Fire-resisting walls and floors.
- Service penetrations for cables, pipes and ducts.
- Fire stopping around openings and junctions.
- Accessible risers and ceiling voids.
- Interfaces between compartment walls, floors and fire door assemblies.
We offer visual and intrusive surveys, with the inspection scope agreed for the building. Intrusive surveys involve opening selected areas to examine concealed construction.
Our reports record findings with photographs and location information, explain inspection limitations and recommend remedial action. Where required, we can also provide cost management and project management support for remedial works.
Fire door surveys
A fire door survey examines the door assembly, including its leaf, frame and associated components, to identify defects that could affect its ability to resist fire and smoke.
Anstey Horne surveys communal fire doors and flat entrance doors. Depending on the agreed scope, inspections consider:
- Door leaf and frame condition.
- Gaps and clearances.
- Hinges, latches and other ironmongery.
- Self-closing devices.
- Intumescent strips and smoke seals.
- Glazing and visible damage or alterations.
Findings help owners and managing agents plan maintenance, repairs, further investigation or replacement where necessary.
Detailed surveys and routine checks
A specialist fire door survey and a routine condition check have different purposes.
For residential buildings in England containing two or more domestic premises, where the top storey is more than 11 metres above ground level, the Responsible Person must:
- Check communal fire doors at least every three months.
- Use best endeavours to check flat entrance fire doors at least every 12 months.
These routine checks do not replace investigation of concerns about a door’s specification, installation or suitability. Fire doors in buildings below this height also require appropriate maintenance. For more information see the government’s fire door guidance.
Frequently asked questions
Does a fire risk assessment replace a compartmentation survey?
A fire risk assessment considers compartmentation as part of the overall assessment of risk. Where the available evidence or accessible inspection raises concerns about concealed construction, a separate compartmentation survey may be recommended.
How often should a fire risk assessment be reviewed?
Under the Fire Safety Order in England and Wales, assessments must be reviewed regularly and kept up to date. A review is particularly necessary where there is reason to suspect the assessment is no longer valid or there has been a significant relevant change.
The review interval should reflect the premises and their risks. The Order does not set a single annual review requirement for every building.
What information should I provide when commissioning a survey?
Useful information includes the building’s address, use, height, occupancy, floor plans, existing fire strategy, previous assessments and records of remedial works. For fire door surveys, provide the approximate number and location of doors where known.
Explain any access restrictions so these can be considered when agreeing the scope.
What happens after the assessment or survey?
The findings provide a basis for planning and prioritising action. The person responsible for the building should arrange necessary work, maintain records and obtain appropriate evidence that defects have been addressed.
Discuss your fire risk management requirements
Whether you need an assessment for one property or surveys across a portfolio, contact Anstey Horne to discuss the building, your concerns and the appropriate scope of work.
Request Expert Advice
Anstey Horne provides expert Fire Risk Management advice to help clients identify, assess and manage fire safety risks across their properties, giving them confidence that appropriate measures are in place to protect occupants and meet their legal obligations.